CC%2 Dynamic test ID=%4 aborted: Error in B channel: test ID=%5
Heidenhain · TNC CNC Controllers
¿Qué significa 231-E023 ?
This error occurs during the dynamic test of PLC peripheral devices (PL, MB, UEC) in the Heidenhain TNC CNC Controller. It signifies that the expected signal transition from 0 to 1 on the TEST.B output was not detected. This indicates a problem with the wiring of the TEST.B output, a short circuit, or an incorrect firmware version of the peripheral device, preventing proper safety function verification.
Causas comunes
- Incorrect wiring of the TEST.B output, such as an open circuit, loose connection, or wrong termination.
- A short circuit present on the TEST.B output line, preventing the signal from switching correctly.
- Incompatible or incorrect firmware version installed on the PLC peripheral device (PL, MB, UEC).
- A hardware defect within the PLC peripheral device itself, preventing the TEST.B output from functioning correctly.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Check the wiring of the TEST.B output for continuity, correct terminations, and any signs of damage, insulation breakdown, or short circuits.
- 2
Verify that the software version of the Heidenhain TNC CNC Controller and the firmware version of the PLC peripheral device are compatible and up-to-date according to Heidenhain documentation.
- 3
Perform a software or firmware update on the controller and/or the peripheral device if outdated or incompatible versions are identified.
- 4
Isolate the peripheral device if possible and test the TEST.B output's voltage transition using a multimeter; if it remains static, the device may be faulty.
- 5
If troubleshooting efforts do not resolve the issue, contact a Heidenhain service agency for further diagnosis or potential replacement of the faulty device.