Traduciendo...
2036
Grid overfrequency
Huawei · SUN2000-(3KTL-10KTL)-M1 Solar Inverter
¿Qué significa 2036 ?
The actual power grid frequency is higher than the requirements for the local power grid code. This indicates an exception in the power grid's frequency stability.
Causas comunes
- Power grid exception: The actual power grid frequency is higher than the requirements for the local power grid code.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Monitor if the alarm occurs occasionally, indicating a temporary power grid abnormality. The SUN2000 automatically recovers when the grid stabilizes.
- 2
If the alarm persists, check whether the power grid frequency is within the acceptable range. If not, contact the local power operator. If it is, modify the grid overfrequency protection threshold through the app, SmartLogger, or NMS with consent from the local power operator.
Datos técnicos verificados. Última actualización: March 2026
Fallas relacionadas
Fuente: Huawei SUN2000-(3KTL-10KTL)-M1 Solar Inverter