2001
High String Input Voltage
Huawei · SUN2000 Solar Inverter
¿Qué significa 2001 ?
The open-circuit voltage of the PV array exceeds the maximum input voltage limit of the SUN2000 due to an excessive number of PV modules connected in series. This indicates a potential overvoltage condition for the inverter's DC input.
Causas comunes
- Excessive PV modules are connected in series in the PV array. Therefore, the open-circuit voltage exceeds the maximum input voltage of the SUN2000.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Check the number of PV modules connected in series in the PV string.
- 2
Ensure that the PV string open-circuit voltage is no greater than the maximum operating voltage of the SUN2000.