2011
String Reversed
Huawei · SUN2000 Solar Inverter
¿Qué significa 2011 ?
The polarity of a PV string connected to the SUN2000 is reversed. This can cause the inverter to stop generating power and potentially damage internal components if not corrected.
Causas comunes
- The PV string is reversely connected.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Check whether the PV string is reversely connected to the SUN2000.
- 2
Wait until the solar irradiance declines at night and the PV string current drops to below 0.5 A.
- 3
Set the DC SWITCH to the OFF position.
- 4
Correct the string polarity.
Datos técnicos verificados. Última actualización: March 2026