Traduciendo...
2012

String Current Backfeed

Huawei · SUN2000 Solar Inverter

¿Qué significa 2012 ?

A PV string has a lower end voltage compared to other strings, often due to an insufficient number of series-connected modules or shading. This can lead to current flowing back into the string, reducing overall system efficiency.

Causas comunes

  • Only a few PV modules are connected in series in the PV string, causing the end voltage to be lower than other PV strings.
  • The PV string is shaded.
  • The open-circuit voltage of the PV string is not normal.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Check whether the PV modules connected in series in the PV string are enough. If not, add more modules.

  2. 2

    Check whether the PV string is shaded.

  3. 3

    Check whether the open-circuit voltage of the PV string is normal.

Ver todos los códigos en este manual (33)
Datos técnicos verificados. Última actualización: March 2026

Fallas relacionadas