Grid Overfrequency

Huawei · SUN2000 Solar Inverter

¿Qué significa 2036 ?

The actual power grid frequency is higher than the standard requirement for the local power grid. This condition indicates an unstable grid frequency, which can cause the inverter to disconnect for protection.

Causas comunes

  • Power grid exception: The actual power grid frequency is higher than the standard requirement for the local power grid.
  • The power grid may be abnormal temporarily.
  • The grid overfrequency protection threshold is set incorrectly.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Check whether the grid frequency is within the acceptable range.

  2. 2

    Log in to the mobile phone app, SmartLogger, or NMS to modify the grid overfrequency protection threshold with the consent of the local power operator.