2085

Built-in PID operation abnormal

Huawei · SUN2000 Solar Inverter

¿Qué significa 2085 ?

This Minor alarm indicates an issue with the built-in Potential Induced Degradation (PID) operation. It can be caused by low output resistance of PV arrays to ground or low system insulation resistance, affecting the compensation function.

Causas comunes

  • The output resistance of PV arrays to ground is low.
  • The system insulation resistance is low.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Turn off the AC output switch and DC input switch.

  2. 2

    Wait for the specified time (as per device safety warning label), then turn on the DC input switch and AC output switch.

  3. 3

    Check the impedance between the PV array output and the ground. Rectify any short circuits or insufficient insulation.

Ver todos los códigos en este manual (33)
Datos técnicos verificados. Última actualización: March 2026