2086
External Fan Abnormal
Huawei · SUN2000 Solar Inverter
¿Qué significa 2086 ?
An external fan (FAN 1-3) is experiencing an abnormality such as a short circuit, insufficient power supply, or a blocked air channel. This Major alarm indicates inadequate cooling for the inverter, which can lead to overheating.
Causas comunes
- The external fan is short-circuited.
- The power supply for the external fan is insufficient.
- The air channel for the external fan is blocked.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Shut down the fan.
- 2
Turn off the DC switch.
- 3
Check whether the fan blades are damaged and clear any foreign matter around the fan.
- 4
Reinstall the fan.
- 5
Turn on the DC switch.
- 6
If the fault persists after 15 minutes, replace the external fan.