Heatsink overtemperature warning power supply unit
Indramat · CLM01.3-M Flying Cutoff Control
¿Qué significa E350 ?
The heatsink temperature of the Indramat HVE or HVR power supply unit has reached its permissible limit, opening the temperature pre-warning contact. Power will be switched off after 30 seconds if the condition persists, indicating potential thermal overload of the DIAX04 SSE-03VRS.
Causas comunes
- The load on the power supply unit is too high, leading to excessive heat generation.
- The ambient temperature within the control cabinet or operating environment is above the specified limit.
- Cooling air ducts are blocked, restricting airflow to the heatsink.
- The internal cooling blower of the HVE/HVR unit is defective or obstructed.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Reduce the operational load on the power supply unit to decrease heat generation.
- 2
Measure and reduce the control cabinet's internal temperature to within specified operating limits.
- 3
Inspect and clear any obstructions in the cooling air ducts or ventilation openings of the Indramat DIAX04 SSE-03VRS power supply unit.
- 4
Verify the operation of the internal blower; if it's defective, the power supply unit requires replacement.