Traduciendo...
F6024

Maximum braking time exceeded

Indramat · Indradrive

¿Qué significa F6024 ?

The drive has exceeded the maximum allowable braking time during a deceleration sequence. This means the motor or load took too long to come to a stop or reduce its speed, often indicating an issue with the braking system or excessive inertia.

Causas comunes

  • Insufficient braking torque or worn mechanical brakes.
  • Excessive inertia of the load relative to the drive's braking capacity.
  • Incorrectly configured deceleration ramp or braking parameters (e.g., S-0-0078 Ramp Time Neg).
  • Faulty braking resistor or chopper circuit.
  • External forces or continuous regenerative load.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Check the mechanical brakes (if present) for proper function and wear, ensuring they provide adequate braking torque.

  2. 2

    Verify the drive's deceleration ramp parameters (e.g., S-0-0078 Ramp Time Neg) are set appropriately for the application's inertia.

  3. 3

    Ensure the braking resistor is correctly sized and connected, and its chopper circuit within the drive is functioning.

  4. 4

    Inspect the mechanical system for any binding or high friction that would prolong deceleration.

  5. 5

    If applicable, verify that there are no external forces or continuous regenerative loads hindering deceleration.

Ver todos los códigos en este manual (60)
Datos técnicos verificados. Última actualización: March 2026

Fallas relacionadas