Negative travel limit exceeded
Indramat · Indradrive
¿Qué significa F6030 ?
The motor's actual position has exceeded the configured negative software travel limit. This fault indicates that the axis has moved below its allowed minimum position, similar to F6029 but in the opposite direction.
Causas comunes
- Overrun due to excessive inertia or inadequate deceleration.
- Incorrectly configured negative software travel limit parameter.
- Faulty position feedback (encoder) providing erroneous actual position values.
- Control program error commanding movement beyond the limit.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Verify the configured negative software travel limit parameter (e.g., S-0-0XXX Neg Limit) in the IndraDrive.
- 2
Check the motor encoder for proper operation, secure mounting, and reliable signal output.
- 3
Review the motion control program for any commands that might cause overtravel in the negative direction.
- 4
Adjust deceleration ramps to ensure the axis stops within the defined limits, accounting for mechanical inertia.
- 5
Perform a homing or referencing procedure to re-establish the correct position reference.