Emergency-Stop activated
Indramat · Indradrive
¿Qué significa F6034 ?
The external emergency stop circuit connected to the IndraDrive has been activated, commanding an immediate and controlled stop of the motor. This is a safety feature designed to bring the machine to a safe state in an emergency.
Causas comunes
- Emergency stop button pressed.
- Fault in the emergency stop wiring (e.g., broken wire, short to ground).
- Associated safety device (e.g., light curtain, safety gate) triggered.
- Faulty emergency stop relay or safety module.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Verify that no emergency stop buttons or safety devices (e.g., light curtains, safety gates, pull cords) are activated.
- 2
Inspect the emergency stop circuit wiring for any breaks, loose connections, or short circuits.
- 3
Reset the emergency stop circuit and the drive after confirming the cause of activation.
- 4
Check the status of any external safety relays or modules integrated into the emergency stop chain.
- 5
Review the emergency stop logic in the safety controller to ensure proper functionality.