Configuration Error
Kone · Electric Traction Elevators
¿Qué significa ALARM (Config Error) ?
The phone board detects a problem with its configuration, manifesting as either a missing configuration or an incorrect one. This is indicated by a specific fast blinking pattern (0.3 s ON, 0.3 s OFF, 0.3 s ON, 2 s OFF). A configuration error can prevent the system from operating correctly, impacting communication and alarm processing capabilities.
Causas comunes
- The configuration data has not been successfully downloaded or stored on the phone board.
- The existing configuration data on the phone board is corrupted or incomplete.
- Incorrect parameters or settings have been loaded onto the phone board during a previous configuration attempt.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Perform a new configuration download to the phone board; utilize the DTMF configuration mode to ensure proper transfer.
- 2
Compare the downloaded configuration parameters with the official system specifications for the KONE Remote Monitoring system (KRMS).
- 3
If persistent, inspect the phone board for any physical damage or signs of component failure that could affect configuration storage.