Traduciendo...
BATT (Failure)

Battery Failure

Kone · Electric Traction Elevators

¿Qué significa BATT (Failure) ?

The backup battery for the phone board has failed, indicated by the BATT LED being ON (Red). This critical fault signifies that the battery needs replacement or its fuse has blown, compromising the system's ability to operate during main power outages.

Causas comunes

  • The backup battery has reached its end of service life and can no longer hold an adequate charge.
  • The battery fuse on the phone board is open, preventing current flow to or from the battery.
  • Internal failure within the battery pack, such as a shorted cell, has occurred.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Check the battery fuse located on the phone board; verify its continuity with a multimeter and replace if blown.

  2. 2

    Measure the voltage of the backup battery at its terminals; if significantly below nominal voltage or if it fails a load test, replace the battery.

  3. 3

    Inspect the battery charging circuit on the phone board by measuring charging current/voltage at the battery terminals when main power is present.

Ver todos los códigos en este manual (13)
Datos técnicos verificados. Última actualización: March 2026

Fallas relacionadas

Fuente: Kone Electric Traction Elevators
Kone BATT (Failure) Battery Failure: Diagnóstico y causas | ErrorLib