26032
IxT overload error, KPP/KSP (axis)
Kuka · KR C4 Controller
¿Qué significa 26032 ?
This fault indicates that an axis connected to a KPP/KSP drive is experiencing an IxT overload, meaning the mean continuous current is too high or the axis is excessively loaded. This can lead to overheating and potential damage to the motor or drive if not addressed.
Causas comunes
- Excessive load in the robot program during start-up or operation
- Modifications to the system increasing load
- Temperature influences affecting motor/drive capacity
- Mean continuous current being too high
- Excessive load causing power overload
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Review and adapt program velocity to reduce load during operation.
- 2
Check machine for mechanical issues.
- 3
Check trace recording of axis current for overload peaks.
- 4
Check CBS pressure.
- 5
Check gear unit for proper function and lubrication.
- 6
Reinitialize the drive bus by cycling Power Off / Power On.