26034

Overcurrent, KPP/KSP (axis)

Kuka · KR C4 Controller

¿Qué significa 26034 ?

This fault signifies a brief overcurrent condition that exceeds the maximum current capacity of the KPP drive. This is typically caused by a short-circuit, leading to immediate drive protection actions.

Causas comunes

  • Short-circuit in the motor or motor cable
  • Brief fault leading to current exceeding KPP maximum current

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Review trace recording of axis current for overcurrent events.

  2. 2

    Check the motor for internal faults or winding issues.

  3. 3

    Inspect the motor cable for short-circuits or damage.

  4. 4

    Reinitialize the drive bus by cycling Power Off / Power On.

  5. 5

    Check the KSP module for any status indicators.

  6. 6

    Check the KPP module for any status indicators.

Ver todos los códigos en este manual (21)
Datos técnicos verificados. Última actualización: March 2026