Traduciendo...
E39

Compressor Discharge Temperature Sensor (THOD) Defective

Mitsubishi Electric · R410A Systems

¿Qué significa E39 ?

The compressor discharge temperature sensor (THOD) is defective (resistance is open circuit) or has a poor connection to the outdoor unit PCB. This prevents accurate monitoring and protection of compressor discharge temperature, risking compressor damage.

Causas comunes

  • Compressor discharge temperature sensor (THOD) failure.
  • Wiring to the THOD sensor is damaged or disconnected.
  • THOD sensor reading is erratic or out of range.
  • Internal failure of the THOD sensor.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Measure the resistance of the THOD sensor at its leads — compare to a resistance-temperature chart if available.

  2. 2

    Inspect the THOD sensor's connector on the outdoor unit PCB — verify it is securely seated and free from corrosion.

  3. 3

    Check for damage to the sensor wiring between the sensor and the PCB using a multimeter for continuity.

Ver todos los códigos en este manual (60)
Datos técnicos verificados. Última actualización: March 2026

Fallas relacionadas

Fuente: Mitsubishi Electric R410A Systems