E49
Low Pressure Fault / Low Voltage Detected
Mitsubishi Electric · R410A Systems
¿Qué significa E49 ?
The system has detected either a low refrigerant pressure condition or a low voltage condition. Low pressure often indicates insufficient refrigerant charge, while low voltage points to power supply issues to the outdoor unit.
Causas comunes
- Refrigerant system pressure is too low, potentially due to a leak or low charge.
- Low voltage detected at the system's power input (e.g., below P1-24VDC).
- Operation under conditions that cause abnormally low suction pressure.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Measure system low-side pressure using manifold gauges — perform leak detection and recharge if low.
- 2
Measure incoming AC line voltage at the outdoor unit's main power terminals — compare to nameplate requirements.
- 3
Check for loose power connections at the outdoor unit's main terminal block and internal wiring.
Datos técnicos verificados. Última actualización: March 2026