Otis · DSD 412 DC Elevator Drive
¿Qué significa 901 ?
Current flow in excess of 300% of the rated armature current is detected within the armature circuit. This indicates a severe overload, a fault in the motor, or a measurement error.
Causas comunes
- Ground fault or an intermittent connection within the motor armature circuit.
- Malfunction or failure of the current measuring module.
- Suboptimal tuning or configuration of the current regulator.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Inspect the motor armature circuit for any ground faults or intermittent connections.
- 2
Test the current measuring module for accurate readings and replace if faulty.
- 3
Review and adjust the current regulator tuning parameters.