Traduciendo...
903
LINE SYNCRONIZATION FAULT
Otis · DSD 412 DC Elevator Drive
¿Qué significa 903 ?
The Phase Locked Loop (PLL) has lost synchronization with the 3-phase AC input power supply. This sets the Severe Fault flag, forces the DSD 412 current reference to zero, and shuts down the drive. This fault is generally caused by AC input power problems, is often self-correcting, and may occur in conjunction with an F904 fault. A CPU Reset is required.
Causas comunes
- Problems with the 3-phase AC input power quality, such as voltage fluctuations or frequency deviations.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Monitor the 3-phase AC input power supply for stability, voltage, and frequency variations.
- 2
Perform a CPU reset on the Drive Control PCB once the AC input power issues have been resolved.
Datos técnicos verificados. Última actualización: March 2026
Fallas relacionadas
Fuente: Otis DSD 412 DC Elevator Drive