Traduciendo...
F917
REVERSED ARMATURE FEEDBACK WIRES
Otis · DSD 412 DC Elevator Drive
¿Qué significa F917 ?
The PCU detected reversed Armature Feedback wires. This fault also occurs if the Armature Feedback wires are not connected, leading to incorrect armature voltage sensing.
Causas comunes
- Armature Feedback wires are reversed.
- Armature Feedback wires are not connected.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Remove power from the drive.
- 2
Reverse the Armature Feedback wires.
- 3
Repeat the diagnostic test until the SCDU displays the 'PASS' message.
Datos técnicos verificados. Última actualización: March 2026
Fallas relacionadas
Fuente: Otis DSD 412 DC Elevator Drive