910

BLOWN FUSE FAULT

Otis · DSD 412 Elevator System

¿Qué significa 910 ?

One or more of the three AC line fuses is open. This condition is checked on power-up and can be confirmed upon request through the PCU F#998 PCU Diagnostics function, via measurements on the Armature Interface PCB, A2.

Causas comunes

  • One or more AC input fuses are blown.
  • Power wiring problem.
  • Faulty DSPR power relay.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Check all AC input fuses for open circuits and replace any blown ones.

  2. 2

    Inspect power wiring for problems.

  3. 3

    Check for a faulty DSPR power relay.

  4. 4

    Use the PCU F#998 PCU Diagnostics function to confirm the fault.