Traduciendo...
923
LOAD CURRENT SETTING FAULT
Otis · DSD 412 Elevator System
¿Qué significa 923 ?
This fault is declared if a number entered for Rated Armature Current, #3, is outside the acceptable range of 0.125 to 2.0 times the bridge current rating. The bridge current rating is determined by the bridge sense resistor on the Cube ID PCB, located on the Armature Interface PCB. This fault requires a DSD power down.
Causas comunes
- Rated Armature Current parameter #3 set outside the acceptable range relative to the bridge current rating.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Enter a valid number for Rated Armature Current, #3, within 0.125 to 2.0 times the bridge current rating (determined by the Cube ID PCB sense resistor).
Datos técnicos verificados. Última actualización: March 2026
Fallas relacionadas
Fuente: Otis DSD 412 Elevator System