938

Low read-back volts from DC bus circuit.

Otis · DSD 412 Elevator System

¿Qué significa 938 ?

This fault indicates that a low voltage read-back is detected from the DC bus circuit. This can occur during Self-Tune (Function #997) or Self-Diagnostic (Function #998). For drives larger than 300 amps DC, this involves discrete wires.

Causas comunes

  • Missing wire connected to the bus voltage feedback circuit.
  • Component problem where the feedback voltage divider ratio does not match the one identified in the Cube ID PCB.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Check for any missing wires connected to the bus voltage feedback circuit.

Ver todos los códigos en este manual (57)