M020
Total Input Power Exceeded
Schindler · Altivar 212 Variable Frequency Drive
¿Qué significa M020 ?
This fault occurs when the accumulated input power value, typically measured in kWh, exceeds the maximum displayable value of 999.999 kWh, indicating a data overflow.
Causas comunes
- Accumulated input power value has exceeded 999.999 kWh.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Clear the accumulated input power value using logic input function 51 (Reset kWh).
- 2
Alternatively, clear the accumulated input power value by setting parameter F748 ([Power cons. memo]) to 0 (Disable) and then cycling power to the drive.