Ot
Overtorque
Schindler · Altivar 212 Variable Frequency Drive
¿Qué significa Ot ?
This fault occurs when the calculated motor torque reaches or exceeds the level set by parameter F616 ([Overtorque level]), indicating that the motor is operating under excessive load and could be damaged.
Causas comunes
- Calculated motor torque has reached the level set by parameter F616.
- Excessive mechanical load on the motor.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Adjust the settings of parameters F615 ([Overtorque det.]) and F616 ([Overtorque level]) as needed.
- 2
Verify the machine operation to identify any mechanical binding or obstructions causing high torque.