SOUt

PM Motor Step-out (Permanent Magnet Motor Pulls Out of Synchronism)

Schindler · Altivar 212 Variable Frequency Drive

¿Qué significa SOUt ?

This fault occurs in permanent magnet motors when the motor pulls out of synchronism, often due to a jammed motor, output phase loss, or sudden impact loads, leading to uncontrolled rotation.

Causas comunes

  • The permanent magnet motor is jammed.
  • Output phase loss to the motor.
  • Sudden impact load on the motor.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Check the mechanical load and correct any jammed conditions.

  2. 2

    Check the condition of the motor windings and load wiring for integrity.