08

Speed monitoring

SEW Eurodrive · MOVIFIT-FC Inverter

¿Qué significa 08 ?

Speed monitoring has been triggered, indicating that the load on the drive is too high, causing the motor speed to deviate beyond acceptable limits. This protective function prevents the motor from operating outside its designed speed range under excessive load.

Causas comunes

  • Actual motor speed deviates significantly from setpoint.
  • Encoder feedback signal loss or corruption.
  • Incorrect speed control loop tuning (e.g., P0338, P0340).
  • Mechanical load changes exceeding drive capability.
  • Parameter P0260 (speed monitoring) threshold too sensitive.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Reduce the mechanical load on the drive.

  2. 2

    Increase the n-monitoring delay time setting in the inverter parameters.

  3. 3

    Reset the fault by switching off the DC 24 V supply voltage.