This fault indicates an incorrect assignment between the motor and the inverter, or an invalid DIP switch setting. The unit cannot properly detect or configure its output stage, preventing correct motor control.
Causas comunes
- Output stage fault detected (e.g., short circuit, open circuit).
- Overcurrent or overvoltage on the output.
- Over-temperature of the output semiconductor device.
- Feedback from output stage indicates abnormal condition.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Correct the DIP switch settings on the unit according to the motor/inverter combination.
- 2
Reset the fault by switching off the DC 24 V supply voltage.
Datos técnicos verificados. Última actualización: March 2026
Fallas relacionadas