Traduciendo...
7702

Self-diagnosis / Device fault

SMA · SUNNY TRIPOWER X Solar Inverter

¿Qué significa 7702 ?

The inverter has detected a general internal device fault through its self-diagnosis routine. This indicates a broad malfunction that prevents normal operation and requires further investigation to identify the specific component or system failure.

Causas comunes

  • Undetermined internal device fault.

Pasos de reparación & Lista de verificación

Haga clic en los pasos para seguir su progreso.

  1. 1

    Verify AC grid voltage and frequency stability at the inverter's output terminals against nominal specifications.

  2. 2

    Inspect all DC input wiring, string fuses, and connections for physical damage, corrosion, or looseness.

  3. 3

    Measure individual PV string voltages and currents to confirm they are within the inverter's operating range and balanced.

  4. 4

    Access the inverter's internal event log or diagnostic menu for more detailed sub-codes or specific fault messages related to the self-diagnosis routine.

Ver todos los códigos en este manual (9)
Datos técnicos verificados. Última actualización: March 2026

Fallas relacionadas

Fuente: SMA SUNNY TRIPOWER X Solar Inverter