Traduciendo...
40
Device unknown
Vacon · NX Liquid-Cooled Drive
¿Qué significa 40 ?
An unknown option board or drive has been detected. Subcodes in T.14 provide further detail: S1 (Unknown device), S2 (Power1 not same type as Power2), S3 (NXS or NXP1 and star coupler incompatibility), S4 (Software and control unit incompatible), S5 (Old control board version).
Causas comunes
- An unrecognized option board is connected to the drive.
- Faulty communication handshake with the installed option board.
- Incorrectly seated option board.
- Drive firmware incompatibility with the option board.
- Defective option board.
Pasos de reparación & Lista de verificación
Haga clic en los pasos para seguir su progreso.
- 1
Remove the option board and restart the drive to confirm fault clears.
- 2
Ensure the option board is fully seated in its slot (e.g., Terminal block X3).
- 3
Verify the option board model is compatible with the drive firmware version.
- 4
If a subcode (S1, S2) is present, consult documentation for specific device identification.
- 5
Test the drive with a known good, compatible option board.
Datos técnicos verificados. Última actualización: March 2026
Fallas relacionadas
Fuente: Vacon NX Liquid-Cooled Drive