749
Serial Communication Error during Activation
Fanuc · AC Spindle Motor Alpha i-Beta i Series Parameters
What does 749 mean?
A serial communication error occurred while the Series 16i system was being activated after power-on. This indicates a problem in the communication link to the spindle amplifier, preventing normal startup.
Common Causes
- A serial communication failure occurred during the boot-up sequence.
- The serial device failed to respond within the expected timeout period.
- Incorrect serial port settings (baud rate, parity, stop bits) during activation.
- A physical connection issue with the serial cable or connector.
Repair Steps & Checklist
Click steps to track your progress.
- 1
Verify the serial cable connection between the controller and the device at terminal RS232-A.
- 2
Confirm the serial communication parameters (baud rate, parity) match between the controller and the device.
- 3
Measure the voltage levels on the serial communication lines (TXD, RXD).
- 4
Attempt to establish a basic serial communication test with the device.
Verified technical data. Last updated: March 2026