750

Spindle Amplifier Not Activated (16i)

Fanuc · AC Spindle Motor Alpha i-Beta i Series Parameters

What does 750 mean?

The serial spindle amplifier for Series 16i was not activated normally at power-on time. This suggests an issue with the amplifier's internal readiness or its startup sequence.

Common Causes

  • The spindle amplifier failed to acknowledge the activation command from the controller.
  • Power supply issues to the spindle amplifier during the activation sequence.
  • A fault condition within the spindle amplifier prevented normal activation.
  • Incorrect serial communication setup for the spindle amplifier.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Check the DC bus voltage at the spindle amplifier's power input terminals (L1, L2, L3).

  2. 2

    Verify the serial communication signal status line from the controller to the spindle amplifier.

  3. 3

    Inspect the spindle amplifier's internal status LEDs for any fault indications.

  4. 4

    Confirm the spindle amplifier's unique address is correctly configured.

Browse all codes in this manual (60)
Verified technical data. Last updated: March 2026

Related Faults

Source: Fanuc AC Spindle Motor Alpha i-Beta i Series Parameters