SP0004
Converter Main Power Supply Open Phase
Fanuc · AC Spindle Motor Alpha i-Beta i Series Parameters
What does SP0004 mean?
An open phase condition is detected in the main power supply to the converter unit of the spindle amplifier. This indicates a loss of one or more phases in the AC input.
Common Causes
- Failure of one or more phases in the incoming AC power supply.
- Loose connections at the main power input terminals of the amplifier.
- Faulty internal power factor correction (PFC) circuit.
- Blown input fuse or circuit breaker for the converter.
- Overheating of the converter power components.
Repair Steps & Checklist
Click steps to track your progress.
- 1
Measure the AC input voltages (L1, L2, L3) at the amplifier's power terminals.
- 2
Inspect all power input connections for signs of arcing or corrosion.
- 3
Verify the main circuit breaker supplying power to the amplifier is not tripped.
- 4
Check the status of any internal input fuses within the amplifier.
- 5
Ensure the amplifier is operating within its specified ambient temperature range.
Verified technical data. Last updated: March 2026
Related Faults
Source: Fanuc AC Spindle Motor Alpha i-Beta i Series Parameters