SP0202
Invalid Spindle Number Setting (15i)
Fanuc · AC Spindle Motor Alpha i-Beta i Series Parameters
What does SP0202 mean?
A spindle number greater than the total number of physical spindles is set in parameter No. 5850 for Series 15i. This indicates an incorrect count or assignment of spindles.
Common Causes
- Invalid spindle number setting (15i).
- Spindle number assigned is outside the allowed range.
- Configuration error for spindle identification.
- Attempted to use a non-existent spindle number.
Repair Steps & Checklist
Click steps to track your progress.
- 1
Check parameter 5850 (Spindle number selected at power-on/reset time) — verify it does not exceed the total number of physical spindles configured.
Verified technical data. Last updated: March 2026
Related Faults
Source: Fanuc AC Spindle Motor Alpha i-Beta i Series Parameters