SP1245
Communication Data Error (CNC Side, 30i Range)
Fanuc · AC Spindle Motor Alpha i-Beta i Series Parameters
What does SP1245 mean?
A communication data error was detected on the CNC side for Series 30i (codes SP1245 to SP1247). This indicates data corruption during transfer to the CNC.
Common Causes
- Data corruption during transmission between CNC and spindle amplifier (30i range).
- Timing issues with data packets on the communication bus.
- External electromagnetic interference affecting data integrity.
- Faulty transceiver chip on either the CNC or amplifier communication board.
- Incorrect data framing or synchronization within the communication protocol.
Repair Steps & Checklist
Click steps to track your progress.
- 1
Measure the signal integrity of the communication bus using a network analyzer.
- 2
Verify that parameter P1-54 (communication settings) is accurately configured.
- 3
Temporarily disable other peripherals connected to the same bus to rule out interference.
- 4
Check for loose connections or damaged shielding on communication cables.
- 5
Initiate a data transfer test and monitor for retransmissions or errors.
Verified technical data. Last updated: March 2026
Related Faults
Source: Fanuc AC Spindle Motor Alpha i-Beta i Series Parameters