SP0140

Count Error Alarm

Fanuc · αi Series AC Servo Motor and Spindle

What does SP0140 mean?

The number of pulses between one phase Z and another (e.g., phase A/B) is shifted by 4λ or more. This indicates a significant discrepancy in the encoder feedback signals, affecting accurate position tracking.

Repair Steps

  1. 1

    Check the wiring and shielding of the pulsecoder feedback cables (e.g., K16/K97) for loose connections or damage.

  2. 2

    Verify the correct phasing and amplitude of the A, B, and Z signals from the pulsecoder using an oscilloscope.

  3. 3

    Inspect the pulsecoder for any physical damage or contamination on the sensor ring that could disrupt pulse counting.

Browse all codes in this manual (29)
Verified technical data. Last updated: March 2026
Source: Fanuc αi Series AC Servo Motor and Spindle
Fanuc Error SP0140: Count Error Alarm — Troubleshooting Guide | ErrorLib