What does 425 mean?
This alarm is issued when the fan motor built into the servo amplifier module, used for internal agitation, has failed. The fan motor is a consumable component, and its failure can lead to overheating of the servo amplifier if not addressed.
Common Causes
- Fan motor built into the servo amplifier module has failed
- Fan clogged with foreign matter
- Power connector of the fan is improperly connected
Repair Steps
- 1
Check that the fan is not clogged with foreign matter
- 2
Check that the power connector of the fan is connected properly
- 3
Replace the fan or the entire servo amplifier module
Verified technical data. Last updated: March 2026
Source: Fanuc αi series AC Servo Motor