C

Alarm of Power Supply (ECM)

Fanuc · Macro B CNC Programming

What does C mean?

A general alarm condition has occurred within the power supply unit of the Energy Charge Module (ECM). This indicates a problem with the main power input to the ECM or its internal power conversion circuitry.

Repair Steps

  1. 1

    Immediately stop the machine using the emergency stop button and open the external Main Circuit Contactor (MCC) of the Power supply.

  2. 2

    Check the incoming main power supply voltage and frequency to the αi PS or power supply module; ensure it is within the specified range (e.g., 200-240 VAC for 200V series, 400-480 VAC for 400V series).

  3. 3

    Inspect the circuit breakers and magnetic contactors connected to the power supply for tripping or damage (Section 3.1.3.10, page 95).

  4. 4

    Verify that the power supply wiring (Cable K1, Section 9.3.1.1, page 213) is securely connected and has the correct cross-sectional area.

  5. 5

    If an external power transformer is used, check its input and output voltages for correctness and stability (Section 3.1.3.7, page 89).

Browse all codes in this manual (26)
Verified technical data. Last updated: March 2026
Source: Fanuc Macro B CNC Programming