P

Communication Error (ECM)

Fanuc · Macro B CNC Programming

What does P mean?

A communication error occurred between Energy Charge Module (ECM) units or with connected devices. This indicates a problem in the data exchange between the ECM's Control Module (A06B-6158-H010) and other connected units like the Servo amplifier or PMC.

Repair Steps

  1. 1

    Immediately stop the machine using the emergency stop button and open the external Main Circuit Contactor (MCC) of the Power supply.

  2. 2

    Inspect all communication cables (e.g., K21, K24 on page 575) connecting the ECM Control Module to other modules (Servo amplifier, I/O) for secure connections and physical damage.

  3. 3

    Verify the communication settings and parameters in the ECM Control Module and connected devices to ensure they are correctly configured.

  4. 4

    Check for external electrical noise that could interfere with communication signals; ensure signal lines are properly shielded and separated from power lines (Section 5.3, page 108).

  5. 5

    Ensure that all connected modules are powered on in the correct sequence, as incorrect timing can lead to communication issues.

Browse all codes in this manual (26)
Verified technical data. Last updated: March 2026
Source: Fanuc Macro B CNC Programming