U

Energy Supply Stop (ECM)

Fanuc · Macro B CNC Programming

What does U mean?

The potential difference across the Energy Charge Module's (ECM) Capacitor Modules is detected to be more than 300V, indicating an unsafe high voltage condition. This suggests a failure in the charging or discharge control, or a dangerous energy imbalance within the module.

Repair Steps

  1. 1

    Immediately stop the machine using the emergency stop button and open the external Main Circuit Contactor (MCC) of the Power supply.

  2. 2

    Measure the voltage across the Capacitor Modules (A06B-6158-H020) to confirm it exceeds 300V.

  3. 3

    Inspect the ECM Control Module (A06B-6158-H010) for proper regulation of charging and discharging operations.

  4. 4

    Check the Resistor Module (A06B-6158-H030) and its connections to ensure it can properly dissipate energy when commanded or during an emergency stop.

  5. 5

    Verify the main power supply and connected regenerative units for stable operation and correct voltage levels to prevent overcharging of the capacitor modules.

Browse all codes in this manual (26)
Verified technical data. Last updated: March 2026
Source: Fanuc Macro B CNC Programming