ALM LED Blink (1:1)

Broken Wire or Noise (Subsequent Unit)

Fanuc · R-30iB Mate + Mate Plus Robot

What does ALM LED Blink (1:1) mean?

The red ALM LED blinks with a 1:1 duty cycle (0.5s ON / 0.5s OFF), indicating a broken wire or poor cable connection between the unit of interest (JD1A connector) and a subsequent unit (JD1B connector). Electromagnetic noise around the cable is also a potential contributing factor to this communication issue.

Repair Steps

  1. 1

    Check for a defective cable or a poor cable connection between JD1A on the unit of interest and JD1B on a unit subsequent to that unit.

  2. 2

    Check to see if there is noise present around the cable.

Browse all codes in this manual (53)
Verified technical data. Last updated: March 2026
Source: Fanuc R-30iB Mate + Mate Plus Robot