SRVO-023
Excessive Position Error at Stop
Fanuc · R-30iB Mate + Mate Plus Robot
What does SRVO-023 mean?
When the servo is commanded to stop, the actual position error is abnormally large. This can occur if the motor brake fails to release properly, or if there is a physical obstacle preventing the robot from maintaining its commanded stop position.
Repair Steps
- 1
If the brake is not released (check for absence of clack sound or vibration), check the continuity of the brake line in the robot connection cable and the mechanical unit cable.
- 2
If no disconnection is found and the brake is still not released, replace the 6-Axis servo amplifier or the servo motor.
- 3
If the brake is released, check whether an obstacle is disturbing the robot's motion.
Verified technical data. Last updated: March 2026
Source: Fanuc R-30iB Mate + Mate Plus Robot