368

SERIAL DATA ERROR(INT)

Fanuc · Series 0i-D/0i Mate-D Maintenance

What does 368 mean?

This alarm on Fanuc Series 0i-D/0i Mate-D with αi/βi Pulsecoders signifies a communication interruption with the built-in Pulsecoder. Common causes are cable disconnection, Pulsecoder failure, or external noise.

Common Causes

  • Physical disconnection or damage to the Pulsecoder communication cable.
  • Internal failure of the Pulsecoder preventing serial data transmission.
  • Electrical noise interfering with the serial data communication.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Inspect the Pulsecoder cable for physical damage, such as cuts, abrasions, or crushed sections.

  2. 2

    Verify all connections of the Pulsecoder cable are secure at both the Pulsecoder and the servo amplifier.

  3. 3

    Check for and mitigate sources of electrical noise (e.g., from power lines, solenoids) that could interrupt serial communication.

  4. 4

    Perform a continuity test on each conductor of the Pulsecoder cable to rule out internal wire breaks.

  5. 5

    If cable integrity and noise issues are ruled out, replace the Pulsecoder unit.

Browse all codes in this manual (60)
Verified technical data. Last updated: March 2026

Related Faults

Source: Fanuc Series 0i-D/0i Mate-D Maintenance