606 n AXIS: CNV. RADIATOR FAN FAILURE

CONVERTER RADIATOR FAN FAILURE

Fanuc · Series 0i-D/0i Mate-D Maintenance

What does 606 n AXIS: CNV. RADIATOR FAN FAILURE mean?

This warning signal on the Fanuc Series 0i-D/0i Mate-D αi servo system indicates a failure of the converter radiator fan. This condition (SVWRN4, SVWRN3, and SVWRN1 active) will eventually result in a converter overheat alarm if the cooling issue is not resolved.

Common Causes

  • Failure of the cooling fan responsible for the converter's radiator.
  • Accumulation of dust or debris on the radiator fins or fan blades, impeding airflow.
  • Poor electrical connection or power supply to the radiator fan.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Inspect the converter radiator fan for any physical damage, debris accumulation, or obstructions.

  2. 2

    Verify all electrical connections to the radiator fan for secure contact and proper voltage supply.

  3. 3

    Confirm fan rotation during operation and listen for any abnormal sounds indicative of bearing failure or obstruction.

  4. 4

    Ensure that the radiator fins and air channels for the converter are clean and free of dust or other foreign material.

  5. 5

    If the fan is not operating or is mechanically compromised, replace the converter radiator fan.