IE0006

- OVERTRAVEL ( SOFT 3 )

Fanuc · Series 0i-D/0i Mate-D Maintenance

What does IE0006 mean?

This Fanuc Series 0i-D/0i Mate-D malfunction prevention alarm indicates that the stored stroke check 3 on the negative side for an axis has been exceeded. This is a tertiary software limit, typically used for complex tooling or specific safety zones.

Common Causes

  • NC program error commanding movement beyond the negative software limit 3.
  • Incorrect setting of the software limit parameter for negative stroke check 3.
  • Physical interference from tooling, workpieces, or machine components triggering the third soft limit.
  • Manual jog operation exceeding the defined negative software limit 3.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Examine the NC program for commands that result in the axis exceeding the negative limit of stored stroke check 3.

  2. 2

    Verify the parameter settings for stored stroke limit check 3 on the negative side for the affected axis.

  3. 3

    Inspect for any physical interference from tooling, workpieces, or machine components that trigger this third soft limit.

  4. 4

    Jog the axis in the positive direction to clear the overtravel condition and then reset the alarm.

  5. 5

    Ensure that the tool data and offset values are correctly entered and do not lead to an overtravel condition.

Browse all codes in this manual (60)
Verified technical data. Last updated: March 2026

Related Faults

Source: Fanuc Series 0i-D/0i Mate-D Maintenance