3017
NO M-CODE BEFORE TAP CYCL
Fanuc · Series 0i Manual Guide
What does 3017 mean?
This P/S alarm occurs when a parameter for the M code associated with either a counter tapping command or a normal tapping command is unset (zero) before the tapping cycle begins. This prevents the control from outputting the necessary M code, which is critical for spindle rotation or other pre-tapping operations.
Repair Steps
- 1
Verify and set the M code parameters for the tapping command. For general tapping, check and set parameters No.27196 through 27201, No.27202, No.27204, and No.27206.
- 2
For rigid tapping by work rotation or tool rotation, verify and set parameters No.27208, No.27209, and No.27210.
Verified technical data. Last updated: March 2026
Source: Fanuc Series 0i Manual Guide