950

PMC System Alarm

Fanuc · Series 20 CNC

What does 950 mean?

This alarm indicates a general system error within the Programmable Machine Controller (PMC) of the Fanuc Series 20 CNC. The PMC handles the machine's ladder logic, I/O, and interlock functions, so an error here means basic machine operations, axis movement, or tool changes may be impossible.

Common Causes

  • Error in the PMC ladder program (e.g., syntax error, invalid logic).
  • Faulty PMC hardware or memory module.
  • Loss of PMC parameters or user data due to battery failure.
  • I/O module malfunction or communication error with I/O devices.
  • Excessive noise on the I/O lines affecting PMC operation.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Check the PMC diagnostic screen for any specific sub-alarms or error messages related to the PMC.

  2. 2

    Verify the PMC ladder program for recent changes or known issues. If a backup is available, try reloading a known good program.

  3. 3

    Check the PMC battery (if separate from main CNC battery) and replace if low to prevent parameter loss.

  4. 4

    Inspect all I/O modules and their wiring for loose connections, damage, or short circuits.

  5. 5

    Power cycle the CNC system and PMC to clear any transient errors. If the alarm persists, the PMC module may be faulty.

Browse all codes in this manual (43)
Verified technical data. Last updated: March 2026

Related Faults

Fanuc Error 950: PMC System Alarm — Troubleshooting Guide | ErrorLib