2051

Abnormal residual current

Huawei · SUN2000-(3KTL-10KTL)-M1 Solar Inverter

What does 2051 mean?

The input-to-ground insulation impedance has decreased during the SUN2000 operation. This typically indicates an insulation fault or a temporary issue with external power cabling.

Common Causes

  • The input-to-ground insulation impedance has decreased during the SUN2000 operation.
  • The external power cable may be abnormal temporarily.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Monitor if the alarm occurs accidentally and the SUN2000 automatically recovers after the external power cable abnormality is rectified.

  2. 2

    If the alarm persists or lasts a long time, check whether the impedance between the PV string and ground is too low.