2051
Abnormal residual current
Huawei · SUN2000-(3KTL-10KTL)-M1 Solar Inverter
What does 2051 mean?
The input-to-ground insulation impedance has decreased during the SUN2000 operation. This typically indicates an insulation fault or a temporary issue with external power cabling.
Common Causes
- The input-to-ground insulation impedance has decreased during the SUN2000 operation.
- The external power cable may be abnormal temporarily.
Repair Steps & Checklist
Click steps to track your progress.
- 1
Monitor if the alarm occurs accidentally and the SUN2000 automatically recovers after the external power cable abnormality is rectified.
- 2
If the alarm persists or lasts a long time, check whether the impedance between the PV string and ground is too low.
Verified technical data. Last updated: March 2026