103

DC Over Voltage

Huawei · SUN2000 8-28KTL Solar Inverter

What does 103 mean?

A major fault caused by excessive PV string output voltage, where the open-circuit voltage of the PV string exceeds the maximum operating voltage of the SUN2000. This can damage the inverter's DC input stage and prevents power generation.

Common Causes

  • Too many PV modules connected in series, resulting in the PV string open-circuit voltage being greater than the maximum operating voltage of the SUN2000.

Repair Steps & Checklist

Click steps to track your progress.

  1. 1

    Check the number of PV modules connected in series for the affected string.

  2. 2

    Reduce the number of PV modules connected in series until the PV string output voltage drops to the specified operating range for the SUN2000.

Browse all codes in this manual (26)
Verified technical data. Last updated: March 2026

Related Faults